How To Program Caddx Nx 8 Installation
As complicated as the GE program may look, there are only two things that need be changed for a typical DIY installation, those are:
Zone Types in location 25.
Siren Options in location 37
Entering program mode is simple enough:
Enter * 8 to tell the system you'd like to enter programming
Enter the four digit Installer Code (factory 9713)
If the Installer Code is valid the service LED will begin to flash.
The system is now waiting for you to tell it what module you'd like to program. The control panel is module zero.
Enter 0 # to tell the system you want to program the control panel.
The system is now waiting for you to tell it what programming location you would like to enter. For simplicity I'm going to step you through all the programming that's necessary for a typical do-it-yourself installation. Pay attention to the programming process and terminology, soon you'll be able to take advantage of all the customization possibilities of your system without referring to this guide.
Enter 25 # to go to location 25 (Zone Types)
Enter your 8 hardwire zone types (my example from above is 3 5 5 5 5 6 6 3)
Note: Press * after each digit to store and advance.
The next location you need to program is location 37 that contains your siren options. Segment 1 of location 37 contains a couple of options pertaining to the siren sounding when phone line voltage goes away, a non-monitored alarm system will not have a phone line connected so you'll need to deselect opions 1 and 2. Segment 2 of location 37 has the voltage out instead of siren driver out option, most systems will require voltage out so I'll include this in my programming steps, if you want siren driver out skip the second part of this programming step.
Enter 37 # to go to location 37 (Siren Options)
Deselect options 1 and 2 of segment 1, press * to advance to segment 2
Select option 1 to enable voltage out for siren
Press * to store segment 2 and advance to segment 3
Press # to back out of location 37
You're now through with all the necessary changes for a DIY installation.
Press the exit button twice to exit system programming.
In summary, to program my system with the above chosen zoning and a 12 volt siren output my keypad entries will be:
* 8 9713
0 #
25 # 3*5*5*5*5*6*6*3*
37 # 12 * 1 * #
Exit Exit

Caddx Nx8 Keypad

DL900 is a program that enables you to remotely change any aspect of the programming for the Caddx 8000, 8600, 8600E, 8900DL, 8980, 8980E, 9000, 9000E and NX-8 control panels. The program also allows arming, bypassing zones and disarming the panel control. You may want to check out more software, such as NETEagle. Caddx Nx 8 Programming Manual Caddx Network NX8 Alarm System Manual Featured gesecurity.com. NX8 Alarm Manual / Find, download and program your existing Caddx Network. Caddx Nx 8 Program Manual. Caddx Nx 8 Programming Manual Free eBook Download: programming, AXIOM Series. Download route editor for msts crashes. Nx-8 installation manual the nx-8 networx from caddx. Download DL900 for free. DL900 is a program that enables you to remotely change any aspect of the programming for the Caddx 8000, 8600, 8600E, 8900DL, 8980, 8980E, 9000, 9000E and NX-8 control panels.